MRI COMPARISON CHART, Siemens Magnetom Espree vs. Siemens Magnetom Avanto.

Posted on: 10/11/2012 8:18:21 AM under MRI Scanners

MRI COMPARISON CHART, Siemens Magnetom Espree vs. Siemens Magnetom Avanto.

MRI COMPARISON CHART
Siemens Magnetom Espree vs. Siemens Magnetom Avanto

MRI Model

> Magnetom Espree

> Magnetom Avanto

Company

Siemens Healthcare

Siemens Healthcare

FDA Clearance

YES

YES

Clinical Application

Whole Body

Whole Body

>> MAGNET

Configuration

Ultra-short open bore

Short bore

Type

Superconducting

Superconducting

Field Strength

1.5 T

1.5 T

Homogeneity
(35 or 40cm DSV), Vrms

<5ppm @ 40cm DSV
(24 plane plot)

1.2ppm typ. @ 40 cm DSV
(24 plane plot)

5-Gauss Fringe Field
Radial Axial, m

2.5 4

2.5 4

Cryogen Refill Period

Approximately 10 years

Approximately 10 years

Finished Gantry Weight, kg
(Covered)

5,100 in operation

5,500 in operation

Finished (Covered) Gantry Dimension, cm (L x W x H)

125 x 230 x 225

160 x 230 x 230

>>PATIENT COMFORT

Minimum Finished Bore L-R Diameter, cm
(Closed Magnet)

120 without covers

150 without covers

Minimum A-P Dimension w/ Table Inserted

70 cm

60 cm

Table Width
(moving portion)

54 cm

54 cm

Table Capacity

550 lbs

550 lbs

Table Vertical Travel, cm
(Min height-scanning height)

47 Min H

47 Min H

Table Lateral Movement Range

243 cm

243 cm

Patient Cooling Features

In-bore ventilation (3 levels)

In-bore ventilation (3 levels)

Patient Illumination Features

In-bore lighting (3 levels)

In-bore lighting (3 levels)

Patient Operator
Call & Intercom

YES

YES

>>GRADIENT

Maximum Amplitude
Single Axis, mTm

33

45

Maximum Slew Rate
Single Axis, Tms

170

200

Cooling System Type

Water

Water

>>COMPUTER SYSTEM

CPU Type

Intel Xeon 2x Dual Core

Intel Xeon 2x Quad-Core

CPU Memory Size, MB

4 GB RAM

4 GB RAM

Reconstruction Hardware

2 x AMD Opt. 252 CPU
(Linux 64 bit)

1 Intel Xeon Quad Core

Reconstruction Memory Size

180GB HD, 8GB RAM

438GB HD, 8GB RAM

Image Storage Memory Type

CD-ROM, DVD-R

CD-ROM, DVD-R

Image Storage Media
Image Capacity

25,000 256 x 256

25,000 256 x 256

DICOM 3.0 Classes Supported

YES

YES

Display Monitor Displayable Area (L x W), cm

1280 x 1024 full screen

1280 x 1024 full screen

Simultaneous Scan & Reconstruction

YES

YES

>>RF SYSTEM

Channels
(Min, Max Configuration)

8, 18, 32  

8, 18, 32

Parallel Imaging Features
(name, imageK-space)

iPAT, mSENSE & GRAPPA

iPAT, mSENSE & GRAPPA

>>COILS
(StandardOptional, #of elements, RF channels, parallel imaging support)

Brain

NS

NS

Head

12, 32 opt; 8, 18, 32 opt; iPAT

12, 32 opt; 8, 18, 32 opt; iPAT

Spine

24; 8, 18, 32 opt; iPAT

24; 8, 18, 32 opt; iPAT

Neck

4, 16 opt; 8, 18, 32 opt; iPAT

4, 16 opt; 8, 18, 32 opt; iPAT

Shoulder

Opt 4, 4chan, iPAT

Opt 4, 4chan, iPAT

Body Torso

6, 32; 8, 18, 32 opt; iPAT

6, 32; 8, 18, 32 opt; iPAT

Knee

Opt 8; 8 chan; iPAT

Opt 8, 15; 8, 15 chan; iPAT

Cardiac

6; 8, 18, 32 opt; iPAT

6; 8, 18, 32 opt; iPAT

Breast

Opt 4, 7, 16; 4, 7, 16; iPAT

Opt 4, 7, 16; 4, 7, 16; iPAT

Wrist

Opt 8; 8 chan; iPAT

Opt 8; 8 chan; iPAT

Neurovascular

Up to 28 chan in combination w/ Tim; iPAT

Up to 28 chan in combination w/ Tim; iPAT

Peripheral Vascular

Opt 16; 8, 18, 32 opt; iPAT

Opt 16; 8, 18, 32 opt; iPAT

TMJ

Opt 2; 8, 18, 32 opt; iPAT

Opt 2; 8, 18, 32 opt; iPAT

Others

Foot ankle coil 8 chan

Foot ankle coil 8 chan

>> IMAGING FEATURES

Noncontrast Angiography

YES

YES

Spectroscopy

CSI & SVS

CSI & SVS

Motion Compensating
Radial Techniques

Std 2-D PACE

Std 2-D PACE

Brain Volume Imaging

YES

YES

Minimum Repetition Time

3-D GRE: 1.6 (256 matrix)

3-D GRE: 0.91 (256 matrix)

Minimum Echo Time

3-D GRE: 0.66 (256 matrix)

3-D GRE: 0.22 (256 matrix)

FOV (AP, RL, HF, Min to Max)

0.5cm – 45cm

0.5cm – 50cm

>> POWER REQUIREMENTS

Voltage (line voltage, phases)

380 400 420 440 460 480V

380 400 420 440 460 480V

kVA

85

110

AC, BTUhr
(for entire system)

10 kW34, 146

10kW34, 146

The Bottom Line: Both of these MRI systems are excellent and would enhance any practice, hospital, or imaging center's profile and clinical capacity. What stands out for the Espree is the 70cm bore, which is an important feature for most diagnostic centers. What makes the Espree difficult is the supply and the cost. These units are difficult to locate on the used market and there are great deals of people who are waiting to acquire such a nice MRI. The Avanto is less expensive but can also prove to be difficult to locate on the used market. So if your budget and timeframe allow, the Espree may be the MRI for you.

If you need more information, feel free to contact us anytime.

Posted by:
Nathan Welch
MRI Specialist
407.438.7847   
Nathan@AmberUSA.com

 