The Siemens Definition Flash 256 Slice CT Scanner machine that uses cutting-edge technology to produce high-quality images
Siemens Definition Flash Overview
With its high gantry rotation speed, the scanner can acquire images quickly, reducing the need for sedation or breath-holding in patients. Its advanced imaging technologies like the SAFIRE algorithm and CARE Dose 4D minimize radiation exposure while still producing excellent image quality, and its high spatial and temporal resolution enables the visualization of small anatomical structures and dynamic processes. The scanner is also comfortable for patients, with a wide bore design and low noise levels, and features user-friendly software for streamlined imaging and analysis. With a wide range of applications from routine exams to oncology, the Siemens Definition Flash 256 slice CT scanner is a top-of-the-line medical imaging device that can provide clinicians with highly detailed and accurate information about the body.
Benefits:
High-speed scanning: The scanner’s high gantry rotation speed enables fast scanning times, reducing the need for sedation or breath-holding in patients.
Low radiation exposure: The scanner uses advanced imaging technologies like the SAFIRE (sinogram-affirmed iterative reconstruction) algorithm and CARE Dose 4D to reduce radiation exposure while still producing high-quality images.
High spatial and temporal resolution: The scanner’s advanced detector and reconstruction technologies allow for high spatial and temporal resolution, enabling the visualization of small anatomical structures and dynamic processes.
Wide range of applications: The scanner can be used for a wide range of applications, including routine exams, cardiac imaging, vascular imaging, and oncology.
Patient comfort: The scanner is designed to be comfortable for patients, with a wide bore design and low noise levels.
User-friendly software: The scanner features user-friendly software that makes it easy for operators to perform exams and analyze images.
Features:
Dual Source Technology: It uses two X-ray tubes and two detectors, enabling faster scans and improved image quality with reduced radiation dose.
High-Speed Imaging: The scanner can achieve high temporal resolution, making it ideal for imaging dynamic processes and reducing motion artifacts.
256 Slice Configuration: It offers 256 slices per rotation, allowing for detailed and precise imaging of anatomical structures.
Flash Mode: The Definition Flash technology includes a “Flash” mode that allows for ultra-fast scanning, which is beneficial for patients who are unable to hold their breath or for high-throughput environments.
Low Dose Imaging: Siemens’ advanced algorithms and technologies help to minimize radiation exposure while maintaining high image quality.
Advanced Post-Processing: The system includes sophisticated software for post-processing and image analysis, enhancing diagnostic capabilities.
More Options
Related CT Scanners
What “256 Slice” Means on a Definition Flash, and What to Verify
The number in the title is real, but it is not the number most buyers think it is. Understanding where it comes from changes which questions you ask about a used system.
The number comes from two detectors, not one
The SOMATOM Definition Flash is a dual source scanner. FDA’s 510(k) summary for the system describes it as a computed tomography x-ray system “which features two continuously rotating tube-detector systems.”
Siemens’ own configuration overview lists the detector as 2 x Stellar Detector, the number of slices as 2 x 128, the generator as 200 kW built from two 100 kW generators, and the gantry opening as 78 cm. So 256 is the combined figure across both tube and detector systems rather than 256 rows on a single detector.
That matters when you compare this scanner against a single source 128 slice system. Compare collimation and coverage per rotation, and compare what each system does with the data, not the headline number. The free medical imaging equipment buyers guides cover how to line those figures up.
Read the FDA history narrowly
The 2011 FDA summary for K113342 describes a Stellar-detector configuration with SOMARIS/7 software and cites the earlier K082220 submission as a predicate. That regulatory history does not prove which detector or software appears on a used scanner. Verify the detector type, software version, and build year independently from the serial-specific configuration report.
Two tubes means two sets of records
On a single source CT the tube is one line item. Here it is two.
Ask for the part number, install date, and exposure count for each tube separately. Ask for calibration and alignment records covering both detectors. A Flash with one fresh tube and one near the end of its life is a very different purchase from one with two recent, matched tubes, and a quote that lists “tube” in the singular has not answered the question.
Verify every named software function
SAFIRE, CARE Dose 4D, iMAR, dual energy applications, and Flash Spiral functions can depend on generation, software release, configuration, and applicable licenses. The feature list above does not establish what is active on a particular scanner.
Get the installed license list. Confirm which applications are active on the console. Watch every one you are paying for run during acceptance testing. Where a license has real value in your workflow, get the transfer position confirmed in writing before the system ships.
Site and power
Siemens lists this system at 200 kW (2 x 100 kW), a 78 cm gantry opening, and a table load of up to 307 kg (676 lbs). Those figures drive electrical service, cooling, and how much room the gantry and table actually need.
Have the equipment drawings for the exact system checked against your incoming power, chiller capacity, floor loading, and the door and corridor path from the dock, plus a shielding design from a qualified physicist. Do that before you commit to an install date. If you are weighing this class against a smaller system, start from used CT machines for sale.
Questions buyers ask
Is there one document that answers most of this?
The system configuration report for that serial number. It lists the detector, the software version, and the licensed options in one place. Ask for it alongside the quote, and ask for both tube histories with it.
Why does the detector generation matter on a used system?
The K113342 summary identifies one Stellar-detector and SOMARIS/7 configuration. It does not establish a universal detector-to-software rule for every used Definition Flash. Confirm both fields independently from the configuration report.
Identify the scanner in the inquiry
Amber’s current CT pricing redirect removes the Definition Flash selection. Put “SOMATOM Definition Flash” in the inquiry and request the serial-specific configuration report, separate records for both tubes, the active software options, and the latest quality-control results. Use the Amber contact page for the inquiry until the model-specific redirect is repaired.