Extremely fast processing in a compact body streamlines diagnosis. This compact table-top reader unit has outstandingly high-speed processing to challenge the common misconception of CR.

Fuji Prima T2 Computed Radiography

The Prima-T2 is a compact tabletop CR reader that provides small practices with hospital-grade digital x-ray in a small, affordable package. At just 86 pounds with a footprint of only 3.2 square feet, it is one of the smallest tabletop CR systems available. An exceptional combination of price, speed and image quality, the Prima-T2's throughput ranges from a rapid 47 to a remarkable 72 images per hour, depending on the cassette size. The resulting 100µm images provide excellent resolution and detail, and Fujifilm's advanced processing technology ensures exceptional first-up images.
fuji prima t2 computed radiography

Fuji Prima T2 Computed Radiography gives you the following benefits:


High-speed processing FCR PRIMA T2 is a table-top reader unit which boasts a world-class high processing speed of 73 IPs/hour.In the high speed mode (5 pixels/mm), throughput is enhanced almost 70% compared with FCR PRIMA T (only for IPs of 14″ × 17″ and 14″ × 14″ ). As with all Fujifilm equipment FCR PRIMA T2 is easy to operate. It will help reduce patient waiting time and greatly increase the efficiency of examination workflow.

Space-saving design FCR PRIMA T2, with its light and compact table top design, can be placed on a desk, shelf or anywhere space is limited. As this is a fully digital reader, neither a darkroom nor automatic processor is required. FCR PRIMA T2 can always be installed in the space formally used by a chemistry based processor.

Stable high-quality images Although this is a compact machine its excellent image quality is the same as that produced by the rest of the FCR range. Image Intelligence™, Fujifilm's proprietary image processing technology, enhances image contrast and sharpness, without any deterioration of details. FCR PRIMA T2 supports accurate diagnosis by offering stable and optimized image quality.

The Fuji Prima T2 Computed Radiography provides you with with the following Specification:


Standard Components FCR PRIMA T2 Image Reader (Model: CR-IR 392)

Applicable Console FCR PRIMA Console, FCRView, CR Console, Console Advance

Main Connectable Imagers DRYPIX PRIMA/Smart/Lite/Plus/4000

Time Required for IP Feed / Load Min. 49 sec.

Processing Capacity Up to 73 IPs/hr.

Reading Specification 10 pixels / mm, 5 pixels / mm

Time to Start on Display Min. 33 sec.

Time to Print on DRYPIX PRIMA Approx. 165 sec. (Approx. 155 sec.)* in case of 35 × 43 cm(14″ × 17″ )